If you can see the difference between
clear and black, you will like this test.
STEP
1: SNAPPING
U.S. Patent #:
5159799
Box of 30 Test Ampoules Product Code #: IM96107
Test based upon ASTM - DD 4412-84
LASTS 4 + YEARS
RETAINS Test
Sample
HELPS Reduce
Costs
STEP 2: READING
VISUAL
INSTRUMENT
USED
FOR: Cooling Water
HVAC
Wastewaters
Potable waters
Environmental Testing
Fuel Testing
Lab Screening
Industrial Process Waters
Classroom Education
USED
BY: Line Operators
Lab Techs
Inspectors
Field Engineer/, Sales & Service Personnel
Teachers
USED WITH:
EPA Methods
Or Alone
SRB KOUNT Assayer KIT DATA
TEST KIT SHELF
LIFE - 4 years
# TESTS per
TEST KIT: 30
TEST KIT WEIGHT
- 14 ounces
TEST KIT SIZE
- 3.25 x 2.75 x 5.25
TEST KIT CONTAINER
- Fiber box
TEST
KIT TRANSPORTATION HAZARD Classification - None (DOT
Ground)
TEST
KIT CONTENTS: A kit contains 30 test ampoules, 1 sample
cup and 1 color standard chart. When the 30 tests have been
used, no replacement components are required, just order a new
kit.
TEST KIT OPERATION STEPS:
Using the water to be tested, rinse the Sample/Snapping
Cup 3 times and then fill with aqueous sample.
Place an IME.Test Ampoule tip down into one of the
holes in the bottom of the filled Sample/Snapping Cup and
pull back on the top to break the ampoule tip (see Step
1 on the other side of this sheet). The IME.Test Ampoule
will automatically fill with the aqueous sample.
Gently rock the filled IME.TestTM Ampoule back and forth
for 30 seconds (longer if the sample is cold water) to mix
the test reagent. After mixing, place IME.Test Ampoule
in a 86 to 95 (F) degree environment (I/A 2000, warm room
or radiator). Periodically compare the ampoule color to
the color card to determine end of test and test results.
Or, select a control limit and look once at the IME.Test
Ampoule.
RESULTS TABLES
ELAPSED
TIME
CONDITION
ESTIMATED
cfu/ml
<24 Hours
EXTREME
>1,000,000
24 Hours
HEAVY
>100,000
2 days
MOD/HEAVY
>10,000
3 days
MODERATE
>1,000
4 days
LIGHT
>100
5 days
TRACE
>10
6 days
NEGATIVE
0
See TSB KOUNT Assayer for sulfur oxidizing bacteria
identification.
WHAT IF:
The Sample color is BLUE at the test start?
- The sample water has a high Dissolved Oxygen level.
The initial sample color
is not Blue or Green at the start? - The
sample has a color to it or if clear, the sample
is anaerobic at the start of test.
USING as SAMPLER: If the IME.TestTM Ampoule
is kept at a cool temperature, Biological growth
will be delayed until the sample is brought to a
proper incubation temperature. This feature can
be used to take a sample at site and forward a proper
sample to a lab. Or, if an abnormal field result
is observed, the IME.TestTM Ampoule contents can
be used for additional analysis (Biological or Chemical).
PRIVATE LABEL/CUSTOM
TEST KITS: Private label and/or Customized
TEST KITS are available upon request.