IME Inc.

IME.Test™ - KOOL KOUNT-P Assayer
Total Viable Aerobic Microbe Tester
with DE Neutralizing Broth

RESULTS in HOURS not Days after Sampling

Inhibiters ADDED - NO Pretreatment Needed
No Storage Limitations • Long Shelf Life
Standard TTC/TSB Based BioChemistry

ASTM APPROVED
#D6530

ME.TEST™ - Kool Kount Assayer - P (KKA-P) Test is a special purpose test. The KKA-P test works in the same manner as the regular Kool Kount Assayer Test (KKA) and has all the operating attributes of the regular KKA test. The reverse side of this data sheet contains a summary of product specifications and test operational steps. The end of test color is an opaque to pink or red color change as opposed to the standard yellow to red of the regular KKA product. The difference is that KKA-P test ampoules have DE Neutralizing media add to the normal dose TTC/TSB biochemistry per ampoule. DE Neutralizing media is especially suited for environmental sampling where neutralization of a chemical is important to determine its bactericidal activity. A strongly bacteriostatic substance may contain bacteria held in bacteriostasis but which may still be able to cause problems. The media will neutralize a broad spectrum of antiseptic and disinfectant chemicals including quaternary ammonium compounds, phenolics, iodine and chlorine preparations, mercurials, formaldehyde and gluteraldehyde. For such testing environments and types of analysis, the KKA-P test ampoule can provide superior test results. Species dominant waters require a one-time, simple to perform calibration adjustment. Each KKA-P comes complete with a sample/ampoule, snapping cup, sample ID labels, and results/instruction chart. KKA-P test ampoules can be purchased in boxes of 30 or as single test (Micro Inspector). Test incubation is normally at 95 F but room temperature incubations are possible. Incubation can be performed manually by purchasing a reusable carry incubation tube or using a standard laboratory heat block or oven. Automatic incubation and end of test detection can accomplished by purchasing our low cost Incubator/AutoAnalyzer (model 2012). Special test calibrations/formulations and private labeling are available upon request.

U.S. Patent #:
5159799
5550032

Box of 30 Test Ampoules
Product Code #: IM95077P
EASY to USE

MANUAL
VISUAL
METHOD

or

AUTOMATIC
INSTRUMENT


Start
(yellow)

END
(pink)

Run 2 Tests
Simultaneously

KOOL KOUNT-P Assayer KIT DATA
TEST KIT SHELF LIFE - 4 years
# TESTS per TEST KIT: 30
TEST KIT WEIGHT - 14 ounces
TEST KIT SIZE - 3.25” x 2.75” x 5.25”
TEST KIT CONTAINER - Fiber box
TEST KIT TRANSPORTATION HAZARD Classification - None (DOT Ground)
TEST KIT CONTENTS: A kit contains 30 test ampoules, 1 snapping cup, dechlorinating solution, sample ID labels, Waste Water instructions and a results/instruction chart. Negative control ampoules, sample swabs and buffered sample solution must be ordered separately. When the 30 tests have been used, no replacement components are required, just order a new kit.

TEST NEUTRALIZES: Mercurial, iodine, chlorine, formaldehyde, Glutaraldehyde, Quaternary ammonium compounds, phenols, hexachlorophene, formalin and lecithin ethanol.

MANUAL TEST KIT OPERATION STEPS:
  1. Using the water to be tested, rinse the Sample/Snapping Cup 3 times and then fill with sample water.

  2. Place an IME.Test™ Ampoule tip down into one of the holes in the bottom of the filled Sample/Snapping Cup and pull back on the top to break the ampoule tip (see Step 1 on the other side of this sheet). The IME.Test™ Ampoule will automatically fill.

  3. Gently rock the filled IME.Test™ Ampoule back and forth for 30 seconds (longer if the sample is cold water) to mix the test reagent. After mixing, place IME.Test™ Ampoule in a 95 (F) degree environment (use KKA safety incubation tube in shirt pocket). Periodically, compare the ampoule color to the color card or negative control ampoule to determine end of test and test results. Or, select a control limit and look once at the IME.Test™ Ampoule.

RESULTS TABLES

TIME (Hrs.)
CONCENTRATION
COUNT
GENERAL
cfu/ml
0.5
10(8)
100,000,000
2.5
10(7)
10,000,000
4.0
10(6)
1,000,000
5.5
10(5)
100,000
7.0
10(4)
10,000
9.0
10(3)
1,000
10.0
10(2)
100
12.5
10(1)
10



Incubation Tube

AUTOMATIC TEST KIT OPERATION STEPS:
  1. Break the IME.Test™ Ampoule that you would like to run the test on.
  2. Dry the well mixed (no undissolved powder) Ampoule.
  3. INSERT the Ampoule into one of the test cells and close the cell cover.
  4. Press the "Cell" button until the display screen is showing the cell number you are using.
  5. Press the "Mode" button until the desired incubation mode is reached. (Total Bacteria, Total Coliform, E. Coli, Sulfate Bacteria, Fecal Coliform)
  6. Press "Start" button.
  7. Press "Enter" to begin the test.
  8. The test is finished when the display screen shows hours and count. (Example: 10.0 2e5, this indicates a test time of 10 hours and a count of 2 x 105)

Incubator/Autoanalyzer

USING as SAMPLER: If the IME.Test™ Ampoule is kept at a cool temperature, Biological growth will be delayed until the sample is brought to a proper incubation temperature. This feature can be used to take a sample at site and forward a proper sample to a lab. Or, if an abnormal field result is observed, the IME.Test™ Ampoule contents can be used for additional analysis (Biological or Chemical).

PRIVATE LABEL/CUSTOM TEST KITS: Private label and/or Customized TEST KITS are available upon request.