Product Product#/Supplier Description
NEUTRALIZING
BUFFER
RS-960-4NB (IBP)
BP-PFV-10NB (IBP)
T8178 (MD)
T8178-C (MD)
Pre-Filled Vial with 4ml 100/cs
Pre-Fillled Vial with 10ml 100/cs
Pre-Filled Vial with 5ml 20/box
Pre-Filled Vial with 5ml 100/box
SWABS BP-555 (IBP)
14-959-90 (FS)
Swab Tube, bulk wrap 200/cs
Swab, individually wrapped 1000/cs
PHOSPHATE
BUFFERED
SOLUTION
02-943-25A (FS)
02-943-25B (FS)
Pre-Filled Bottle with 99ml 72/cs
Pre-Filled Bottle with 90ml 72/cs
SAMPLE/WHIRL
PAK BAGS
01-002-30 (FS) 60ml Bag 500/pk
  1. International BioProducts (IBP)
    US & Canada: 800-729-7611
    International: 425-883-1349

  2. Micro Diagnostics (MD) 630-628-6055

  3. Fisher Scientific (FS) 800-766-7000


JUICE APPLICATIONS
APPLICATIONS FOR APPLE JUICE, ORANGE JUICE, MILK, PICKLE JUICE AND SWABS IN KK, CF, AND EC AMPOULES

Our Kool Kount, Coliform and E.Coli ampoules were tested in various foods in a controlled laboratory environment. More than 200 tests were run confirming that KK, CF and EC ampoules give accurate results in samples other than water. Food tests were performed alongside water samples spiked at the same bacteria levels. All tests concluded that the results time tables for water also apply to food.

The following chart explains the test procedure for various foods and environmental samples using KK, CF and EC ampoules.


TEST PROCEDURE
FOOD SAMPLE PREPARATION TEST PROCEDURE DETERMINING RESULTS
APPLE JUICE Make a 1/100 dilution of sample into Phosphate Buffered Saline (i.e.- 0.5 ml into 49.5 ml or 1 ml into 99 ml). 1(a) Pour prepared sample into sample cup. (b) Crack ampoule. (c) incubate 35-37C. 1(a) Check ampoule hourly for color change. (b) *See color change and determine count using results table. (c) Take count from step b and multiply by 100 to get final result.
ORANGE JUICE Filter juice through coffee filter to remove pulp, then proceed as for apple juice. Same as apple juice Same as apple juice
MILK Same as apple juice Same as apple juice Same as apple juice
PICKLE JUICE Same as apple juice Same as apple juice Same as apple juice
EQUIPMENT SWABS 1(a) Take sterile swab dipped in neutralizing buffer and swab equipment surface (12" x 12" area). (b) Place swab in test tube or whirl pak with 25 ml Phosphate Buffered Saline. 1(a) Pour solution from test tube or whirl pak into sample cup. (b) Crack ampoule. (c) Incubate 35-37C. 1(a) Check ampoule hourly for color change. (b) See color change and determine count using results table. *
SWAB of MEAT and POULTRY for SURFACE CONTAMINATION 1(a) Take sterile swab and swab surface of meat (4" x 4" area). (b) Place swab in test tube or whirl pak with 25 ml Phosphate Buffered Saline. Same as equipment swab Same as equipment swab
SEA WATER Make a 1/10 dilution of sample into Phosphate Buffered Saline. ( i.e.- 10 ml into 90 ml ) Same as apple juice 1(a) Check ampoule hourly for color change. (b) *See color change and determine count using results table. (c) Take count from step b and multiply by 10 to get final result.

* Blue fluorescence (EC Ampoule) is best visualized in the dark with a long-wave UV lamp.